T90-0.5C, 17060039
DR7001399 Angular contact bearing
DR7002209 Angular contact bearing
DR7002175 Angular contact bearing
DR7002366 T90-0.5 Spindle
DR7002367 T90-0.5 Gears
DR7000024 Misc. Seals / Grease / etc…
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
- The drive spindle is broke. We recommend replacing the spindle.
- The bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
- The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
- The bearings show some wear on the inner and outer diameters.
- The gears are rough and worn. We recommend replacing the gears.
- The unit will be assembled and tested.
Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967
R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
•The upper and lower bearings show some wear on the inner and outer diameters.
•The tool pressure test checks fine.
•The stator passed the phase and insulation tests.
•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.