PDS Colombo

RV116.2, 0802963, 10Hp, 18000rpm, 220/440v, 300 Hz DR7000089 Motor Rewind DR7000041 Spindle Repair Labor And Assy Inspection Results: The stator passed the phase test, but failed the ground test. We recommend rewinding the stator. The unit will be assembled and tested. Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967 R188213 Lower bearing DR7000057 Upper bearing DR7000240 ... Read More