Eurospindle

Hi-L, 8kw, 24000rpm, 380v, 800 Hz, M.252.0506, HSK63F, 4.297.0606

DR7000730 Lower bearing
DR7000057 Upper bearing
DR7000501 HSK63F Gripper
DR7000024 Fan cover grill
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy

Inspection Results:

  • The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
  • The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
  • The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
  • The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
  • The upper and lower bearings show some wear on the inner and outer diameters.
  • The gripper backed off the drawbar. The gripper is worn and will be replaced.
  • The fan cover grill has broken off. We will fasten a new grill over the fan.
  • The stator passed the phase and insulation tests.
  • The proximity switches work fine and will be set at time of assembly.
  • The unit will be assembled and tested.

Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967

SKF Homag HSK63F tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967

R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy

Inspection Results:

•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.

•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.

•The upper and lower bearings show some wear on the inner and outer diameters.

•The tool pressure test checks fine.

•The stator passed the phase and insulation tests.

•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.

•The unit will be assembled and tested.