T13-00026, MT2005 xx, 6000rpm
DR7001304 Angular contact bearing
DR7001990 Deep groove bearing
DR7001463 Deep groove bearing
DR7001127 Needle roller bearing
DR7000009M Dust Grind Taper – Manual spindle motor or live tool
DR7001854M Plate & Grind Journal – Manual spindle motor or live tool
DR7000039 Bearing Cartridge Repair
DR7002181 Dust grind seal area
DR7000024 Misc. Seals / Grease / etc…
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
- Two of the spindle journal diameters are worn. We recommend plating and grinding these areas.
- One of the seal areas on the journal is rough. We recommend dust grinding this area.
- Two of the bearing housing inner diameters are larger than design specifications and shows some wear. We recommend boring and bushing both housings.
- The taper runout is larger than design specifications. We recommend dust grinding the taper.
- The bearings show some wear on the inner and outer diameters.
- The gears are in good shape and show little wear.
- The unit will be assembled and tested.
Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967
R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
•The upper and lower bearings show some wear on the inner and outer diameters.
•The tool pressure test checks fine.
•The stator passed the phase and insulation tests.
•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.
•The unit will be assembled and tested.