2218.1K07-009
DR7001042 Lower bearing
DR7000996 Upper bearing
DR7002239 Disc spring 162
DR7000024 Replace gripper balls & repair drawbar threads
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
- The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
- The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
- The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
- The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
- The upper and lower bearings show some wear on the inner and outer diameters.
- There are many broken disc springs. We recommend replacing all the disc springs.
- The gripper balls are worn and will be replaced. The drawbar threads will be repaired.
- The unit will be assembled and tested.
Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967
R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
•The upper and lower bearings show some wear on the inner and outer diameters.
•The tool pressure test checks fine.
•The stator passed the phase and insulation tests.
•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.
•The unit will be assembled and tested.
Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967
R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
•The upper and lower bearings show some wear on the inner and outer diameters.
•The tool pressure test checks fine.
•The stator passed the phase and insulation tests.
•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.
•The unit will be assembled and tested.
Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967
R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
Inspection Results:
•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
•The upper and lower bearings show some wear on the inner and outer diameters.
•The tool pressure test checks fine.
•The stator passed the phase and insulation tests.
•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.
•The unit will be assembled and tested.