Perske

KRSV 51.14-2D, 4/5kW, 17450rpm, 350v, 300 hz, 910857

DR7000031 Lower bearing
DR7000028 Upper bearing
DR7000867 Perske Shaft w/ER32 Collet Taper
DR7000632 Perske, Fan VS50/VS60
DR7000039 Bearing Cartridge Repair
DR7000089 Motor Rewind
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy

Inspection Results:

  • The shaft will be replaced per customer request to have an ER32 collet.
  • The upper bearing housing inner diameter is larger than design specifications and shows some wear. We recommend boring and bushing the housing.
  • The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
  • The upper and lower bearings show some wear on the inner and outer diameters.
  • The stator failed the phase test and needs to be rewound.
  • The fan is worn and will be replaced.
  • The unit will be assembled and tested.

Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967

SKF Homag HSK63F tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967

R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy

Inspection Results:

•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.

•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.

•The upper and lower bearings show some wear on the inner and outer diameters.

•The tool pressure test checks fine.

•The stator passed the phase and insulation tests.

•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.

•The unit will be assembled and tested.