Sacarrdo

XS-24 A6 EP8, s/n 143252, 18kW, 960/8000rpm, 400v, 50/400 Hz

DR7000263 Lower bearing
DR7001365 Upper bearing
DR7000745 Upper bearing
DR7000024 Sensor
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy
EXPEDITE FEE Expedite Fee – 5 day

Inspection Results:

  • The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.
  • The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
  • The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.
  • The taper runout is acceptable. Our proposal provides no repair to the spindle taper.
  • The upper and lower bearings show some wear on the inner and outer diameters.
  • The fan has 2 broken fins, but does run. We will leave as is. We are checking on price and lead time for a new fan.
  • One of the proximity switches is broken and will be replaced.
  • The unit will be assembled and tested.

Tool change router spindle, 7.5kW, 24000rpm, 380v, 400 Hz, HSK 63F, s/n 05093967

R188213 Lower bearing
DR7000057 Upper bearing
DR7000240 Proximity Switch
DR7000087 Dynamic Balance Rotating Part
DR7000041 Spindle Repair Labor And Assy

Inspection Results:

•The spindle journal diameters show no appreciable wear and are acceptable for proper bearing fits.

•The upper bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The lower bearing housing inner diameter meets design specifications and shows no appreciable wear. No modification is required.

•The taper runout is acceptable. Our proposal provides no repair to the spindle taper.

•The upper and lower bearings show some wear on the inner and outer diameters.

•The tool pressure test checks fine.

•The stator passed the phase and insulation tests.

•The proximity switches work fine and will be set at time of assembly. The drawbar nut was loose causing the sensor not to read properly. We will replace (1) sensor.

•The unit will be assembled and tested.